What was found
CRACK INDICATION ON LOWER FITTING AROUND THE FASTENER OF CONNECTING PLATE ON FWD HINGE ON RT MAIN LANDING GEAR, REPLACED LOWER FWD FITTING AND FASTENER LOCATED AT FWD POSITION HINGE OF R/H MAIN LANDING GEAR DOOR AS PER SRM 51-72-11 AND DRAWING D53370720.