As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND DENT 13 INCHES AFT OF L1 DOOR UPPER RIGHT HAND CORNER. CUT OUT DAMAGE SKIN UPPER AFT SIDE OF L1 DOOR REF SRM 53-02-01 REPAIR 1. FABRICATED FINGER DOUBLER REF SRM 53-02-01 REPAIR 1. TREATED AND PRIMED FINGER DOUBLER AND FILLERS REF SRM 53-02-01 REPAIR 1. INSTALLED FINGER DOUBLER AND FILLERS REF SRM 53-02-01.