As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BULK CARGO FLOOR STRUCTURE MAIN FRAME LOWER END ATTACH ANGLE IS BROKEN BS 1620 RBL 3.0 (VIEW FROM AFT SIDE). CUT OUT DAMAGED SECTION AND REPAIRED BULK CARGO FLOOR STRUCTURE MAIN FRAME LOWER END ATTACH ANGLE AT STA 1620 RBL 3 IAW ERA 567757-14 REV ORIGINAL.