What was found
CORROSION FOUND ON THE FLOOR SUPPORT Y1162 BETWEEN FRAMES 66 TO 88, AT AFT GALLEY. REPLACED IAW SRM 51-72-11 AND DWG D53472780.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON THE FLOOR SUPPORT Y1162 BETWEEN FRAMES 66 TO 88, AT AFT GALLEY. REPLACED IAW SRM 51-72-11 AND DWG D53472780.