What was found
INITIAL INSPECTION, CRACKED PRODUCTION DOUBLER ON FWD LAVATORY SERVICE PANEL. PRODUCTION DOUBLER ON FWD LAVATORY SERVICE PANEL WAS REPAIRED PER ER/A 569279-14 REV ORIGINAL SEC I AND ETI-88-18-060 REV 4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INITIAL INSPECTION, CRACKED PRODUCTION DOUBLER ON FWD LAVATORY SERVICE PANEL. PRODUCTION DOUBLER ON FWD LAVATORY SERVICE PANEL WAS REPAIRED PER ER/A 569279-14 REV ORIGINAL SEC I AND ETI-88-18-060 REV 4.