As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
OVERWING EMERGENCY LIGHTS WON'T EXTINGUISH AFTER SETTING EMERGENCY LIGHT SWITCH TO OFF AS REPORTED BY 2ND SHIFT (WILL ONLY SWITCH OFF ON 'ARM' POSITION). T/S PER FIM 33-51-00-802. REMOVED AND REPLACED OVERWING EMER EVAC LIGHTS BATTERY PACK RELAY R2-273 IAW AMM 33-51. OPERATIONAL CHECK SATISFACTORY INCLUDING OW EMERG EVAC LIGHTS.