What was found
CORROSION LOWER SILL LOC FR 66 TO FR 68 STR 23L AT AFT GALLEY AREA. REPLACED LOWER SILL AND FASTENER LOCATED FR 66 TO FR 68 STR 23L AT AFT GALLEY AREA AS PER SRM 51-72-11 AND DWG D53480505.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION LOWER SILL LOC FR 66 TO FR 68 STR 23L AT AFT GALLEY AREA. REPLACED LOWER SILL AND FASTENER LOCATED FR 66 TO FR 68 STR 23L AT AFT GALLEY AREA AS PER SRM 51-72-11 AND DWG D53480505.