What was found
CORROSION FLOORBEAM +Y503.2 LOCATED FROM FR 12 TO FR 16 AT FWD GALLEY AREA. REPLACED FLOORBEAM +Y503.2 BTW FR 12 TO FR 16 FWD GALLEY AREA AS PER SRM 51-72-11; 51-42-11 AND DRAWING D53112825.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FLOORBEAM +Y503.2 LOCATED FROM FR 12 TO FR 16 AT FWD GALLEY AREA. REPLACED FLOORBEAM +Y503.2 BTW FR 12 TO FR 16 FWD GALLEY AREA AS PER SRM 51-72-11; 51-42-11 AND DRAWING D53112825.