What was found
6 EMER LIGHTS INOP IN CABIN. FORWARD GALLEY PARTITION LIGHT, FOUND DISCONNECTED GROUND WIRE, RECONNECTED & OPS CHECK GOOD. EAT LIGHT AT 14A: FOUND DISCONNECTED WIRE, RECONNECTED, OPS GOOD. ROW 35, 39, 40, & AFT LAV PARTITION FOUND FAULTY POWER SUPPLY. REMOVED & REPLACED APPLICABLE POWER SUPPLY REF 33-51. OPS CHECK GOOD. SECURED PANELS.