Service difficulty report · Fan · Boeing 757232

Difficulty date
August 7, 2018
Submitted
August 7, 2018
Operation
Air carrier
Aircraft
N6715C
Make and model
Boeing 757232
Aircraft serial
30486
Aircraft time
59,907 hours, 21,612 cycles
Part
Fan
Condition
Failed
Location
Cabin Pressure
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DIVERTED DUE TO A LOSS OF CABIN PRESSURIZATION, AND DECLARED AN EMERGENCY. FOUND THE RT ENG PMA COKED WITH OIL, REPLACED CARBON SEAL. FOUND LT ENG 450F DEGREE SENSOR DAMAGED AND REPLACED. REMOVED AND REPLACED LEFT FAN AIR NORMAL TEMP SENSOR PER IAW AMM 36-11-17. REMOVED AND REPLACED LEFT FAN AIR VALVE IAW AMM 36-11-16. PERFORMED SINGLE PACK PRESSURIZATION CONFIDENCE CHECK IAW 21-51-00-755-622. PHASES 1 THRU 4 CHECKED GOOD.