What was found
DURING INSPECTION, FOUND THE NR 8 SLAT T/E WEDGE WORN OUT OF LIMITS AT SS 383.62 - SS 384.97. THE SLAT WAS REPAIRED IAW ER/A 570565-14, REV ORIGINAL, AND ETI-37-18-461, REV 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND THE NR 8 SLAT T/E WEDGE WORN OUT OF LIMITS AT SS 383.62 - SS 384.97. THE SLAT WAS REPAIRED IAW ER/A 570565-14, REV ORIGINAL, AND ETI-37-18-461, REV 1.