As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INITIAL INSPECTION, CORROSION ON INTERCOSTAL AT FLOOR STRUCTURE AT AFT CARGO COMPARTMENT BTW STA 847-787 AND RBL13.84. LEVEL CORROSION 2, FLOOR STRUCTURE AT AFT CARGO COMPARTMENT BTW STA 767 TO 887 AND RBL13.84 WAS REPLACED PER SRM 51-40-02.