What was found
REVALUATED DENT APPROX 12 IN AFT OF L1 DOOR THERSHOLD, OUT OF LIMITS PER SRM 53-00-01. DENT WAS REPAIRED PER ETI-37-18-506 REV 2 AND ER/A 571433-14 REV ORIGINAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
REVALUATED DENT APPROX 12 IN AFT OF L1 DOOR THERSHOLD, OUT OF LIMITS PER SRM 53-00-01. DENT WAS REPAIRED PER ETI-37-18-506 REV 2 AND ER/A 571433-14 REV ORIGINAL.