What was found
(LP# 0760374) CORROSION FLOOR STRUCTURE WEB LOCATED BETWEEN FRAME 65 TO FRAME 66 AND STRINGER 23R AT AFT GALLEY AREA. REPLACED IAW SRM 51-42-11 AND DWG D53474250.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(LP# 0760374) CORROSION FLOOR STRUCTURE WEB LOCATED BETWEEN FRAME 65 TO FRAME 66 AND STRINGER 23R AT AFT GALLEY AREA. REPLACED IAW SRM 51-42-11 AND DWG D53474250.