What was found
(LOG 0770181) DURING INSPECTION FOUND CORROSION IN TERMINAL FITTING LONGERON NR 22 LT SIDE AT W-2 AREA. TERMINAL FITTING LONGERON NR 22 LT SIDE WAS REPLACED PER SRM 51-40-02 PAR 4,7 AND DWG 147A0070 REV N.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(LOG 0770181) DURING INSPECTION FOUND CORROSION IN TERMINAL FITTING LONGERON NR 22 LT SIDE AT W-2 AREA. TERMINAL FITTING LONGERON NR 22 LT SIDE WAS REPLACED PER SRM 51-40-02 PAR 4,7 AND DWG 147A0070 REV N.