What was found
INITIAL INSPECTION, CORROSION ON PREVIOUS REPAIR DOUBLER OF FLOORBEAM AT STA 365 BTW STA RBL 2.0 TO RBL 24. REPAIR DOUBLER WAS REPLACED PER SRM 53-00-51 FIGURE 201 TABLE 1 REPAIR 5 AND 51-40-02 PAR 7.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INITIAL INSPECTION, CORROSION ON PREVIOUS REPAIR DOUBLER OF FLOORBEAM AT STA 365 BTW STA RBL 2.0 TO RBL 24. REPAIR DOUBLER WAS REPLACED PER SRM 53-00-51 FIGURE 201 TABLE 1 REPAIR 5 AND 51-40-02 PAR 7.