What was found
(LOG 0782606) DURING INSPECTION FOUND CORROSION ON FRAME CLIPS STATION 500G BTW STGR 27L TO 25L. FRAME CLIPS STATION 500G BETWEEN STRINGERS 27L & 25L WERE REPLACED PER SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(LOG 0782606) DURING INSPECTION FOUND CORROSION ON FRAME CLIPS STATION 500G BTW STGR 27L TO 25L. FRAME CLIPS STATION 500G BETWEEN STRINGERS 27L & 25L WERE REPLACED PER SRM 51-40-02.