As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
(LOG 0805850) DURING INSPECTION FOUND CRACKED INTERNAL PRODUCTION DOUBLER ON EXTERNAL POWER RECEPTACLE CUT OUT (FWD EDGE). INTERNAL PRODUCTION DOUBLER ON EXTERNAL POWER RECEPTACLE CUT OUT (FWD EDGE) WAS REPAIRED PER B737-800 S.R.M 53-10-15 REP.5.