What was found
SHIP 5651 -ATO- THRUST MGMT SYS/AUTO THROTTLE INOP ABORTED T/O AT 40 KTS FOR A/T DISCONNECT MASTER CAUTION. CORRECTIVE ACTION: FLIGHT CREW PLACARD INSTALLED IN ATL PER MEL 22-30-01A AND CONTINUED TO MSY. CORRECTIVE ACTION: NO FLT FAULTS RECORDED. PERFORMED TEST 2 TMC PER B757 AMM 22-00. OP CK NORMAL. REMOVED MEL AND PLAC. REVERSED M PROC.