What was found
SMOKE IN COCKPIT, NBR 1 PFD FLICKERED THEN BILLOWING SMOKE, DISSIPATED IN 1 MIN AFTER SMOKE APPEARED. FOUND WATER DRIPPING ON CAPTS PFD. RESEALED WIPER MOTOR SHAFT AREA, RAIN REPELLENT SHAFT, AND SERVERAL AREAS AROUND CAPTS WINDSHIELD. REPLACED CAPTS PFD. OPS CKS GOOD. C/W ODI PREVENTION 2172. OK FOR SERVICE. (LP# 5182665)