What was found
DAMAGE FOUND AFT OF L1 DOOR LOWER EDGE AT STATION 227 AND 1 INCH ABOVE L-20 STRINGER. COMPLIED WITH REPAIR INSTRUCTIONS IAW ER/A 563130-14 REV ORIG. WILL REQUIRE REPEATED INSPECTION EVERY 20 DAYS AND A PERMANENT REPAIR AT OR BEFORE NEXT C-CHECK. NO CRACK INDICATIONS NOTED ON INSPECTION QC4080 (358523). ASSOCIATED ER/A 14-563130 ADDED FOR AC 9542. PERFORMED DVI AND HFEC INSPECTION OF DAMAGE AREA IAW ER/A 563130-14 REV A DATED 31AUG18 SECTION II. NO CRACKS OR ADDITIONAL DAMAGE NOTED (LP #3605989)