What was found
SHIP 5652 INITIAL INSPECTION. CORROSION ON PREVIOUS REPAIR OF DECK PLATE STA 1681-1690 AND RBL 47 AT FLOOR STRUCTURE WET AREA. CORRECTIVE ACTION: NRC 00220 LEVEL CORROSION 2 DOUBLER WAS REPLACED PER SRM. (0900328)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SHIP 5652 INITIAL INSPECTION. CORROSION ON PREVIOUS REPAIR OF DECK PLATE STA 1681-1690 AND RBL 47 AT FLOOR STRUCTURE WET AREA. CORRECTIVE ACTION: NRC 00220 LEVEL CORROSION 2 DOUBLER WAS REPLACED PER SRM. (0900328)