As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
OPEN HOLE ETHF INSPECTION ON LEFT VERT STAB FRONT SPAR FWD FLANGE SHOWS CRACK INDICATION AT 2ND HOLE ABOVE SPLICE REFERENCE 5530-01045-0602. REAMED HOLE SIZE FROM .205 TO .215 (668138) OPEN HOLE BHEC INSPECTION OF SUBJECT FASTENER HOLE OK REF 5530-01045-0602. SDR REPORTED DUE TO BEING AD RELATED. (LP0908078)