What was found
SHIP 5809 ON CLIMB OUT OF SEA NOTICED LEFT WINDOW (CAPT) ELECTRICALTERMINAL GLOWING RED WITH LIGHT ELECTRICAL SMELL. TURNED OFF LEFT FWD WINDOW HEAT AND SMELL AND GLOWING TERMINAL EXTINGUISHED. CORRECTIVE ACTION: REMOVED NR 1 LEFT WINDOW & REPLACED WIRE D3326 A-AC PER WDM 30-41-11. TERMINATED WIRE WDM 30-41-11. REPLACED NR 1 LEFT WINDOW REF AMM 56-11, ACCOMPLISHED ALL 3 TORQUES & APPLIED SEALANT. WIRE HOOK UPS & OPS CK GOOD. AMM 30-41. (4980996)