What was found
CRACK INDICATION ON FRAME 16 LT SIDE AT DOOR STOP FITTING 7 OPEN FASTENER HOLES UPPER IB AND LOWER IB AT FWD GALLEY AREA 2 EA. AFTER SEPARATE LAYERS (FRAME AND INTERCOSTEL) PERFORMED ROTOTES INSPECTION AND FOUND CRACK INDICATION ONLY ON INTERCOSTAL TOOL. REPLACED INTERCOSTAL LOC. AT FR.16 AT STOP FITTING NR 7 UPPER POSITION FWD GALLEY AREA AS PER SRM 51-72-11 AND DRAWING D53112300. JOB COMPLETE.