What was found
DURING INSPECTION FOUND BROKEN WEB - INTERCOSTAL FLOOR STRUCTURE LOC BS 312 TO BS 328 AND RBL 31 AT FWD GALLEY AREA. REPLACED INTERCOSTAL AND FASTENER ON FLOOR STRUCTURE LOC BS 328 AND RBL 31 AT FWD GALLEY AREA AS PER SRM 51-42-02 AND DWG 141A5400 REV 0.