What was found
CORROSION ON LH AFT MOVABLE FLAP VANE AT LH FLAP. (AI). NRC: 00140 CORROSION LEVEL II, CORROSION WAS FOUND OUT OF LIMITS PER B717-200 SRM 57-53-02-0I-1 ITEM 1 AND SRM 57-00-00-1A FIGURE 103. AFT LH MOVABLE FLAP VANE WAS REPLACED PER B717-200 AMM 27-50-03 400-802 AND ADJUSTED PER B717-200 AMM 27-50-03 200-801. TOOL USED TENSIOMETER P/N: T5-2002-101-00, S/N: 74721, D/D: 16JUN19. THERMOMETER P/N: TM360, S/N: QT-1024, D/D: 22FEB19. (LP #0935354)