What was found
SHIP 689 CRACK INDICATION WAS FOUND ON FRAME AT STA 1681 ON A/C 0689 DURING ACCOMPLISHMENT OF WORKCARD. CRACK IS REPORTED AT INBOARD HOLE AT WL 208, JUST BELOW FLOOR LINE. TIME-LIMITED REPAIR TO BE ACCOMPLISHED PER ER/A 575533-14, REV ORIGINAL. CORRECTIVE ACTION: SUMMARY OF NRC 00118: FRAME LH STA 1681 WAS REPAIRED (PERMANENT REPAIR) PER ER/A 575533-14AD REV A SECTION II AND ETI 57-21-528 REV 4. DTE APPROVAL UNDER LOG PAGE #2015936. AMOC APPROVAL UNDER LOG PAGE # 2015942 AND LOG PAGE # 0951535 WAS UP DATE. (0951535)