What was found
THE EMERGENCY LIGHTS AT EXIT ROW 18 ARE INOPERATIVE. MAINTENANCE REPAIRED THE WIRING AT THE OVERHEAD PANEL AND REPLACED THE BATTERY PACK AND BATTERY. OPERATIONAL CHECK WAS GOOD PER B717 WDM 33-51 AND SWPM 20-20.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
THE EMERGENCY LIGHTS AT EXIT ROW 18 ARE INOPERATIVE. MAINTENANCE REPAIRED THE WIRING AT THE OVERHEAD PANEL AND REPLACED THE BATTERY PACK AND BATTERY. OPERATIONAL CHECK WAS GOOD PER B717 WDM 33-51 AND SWPM 20-20.