As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION LEVEL: 2 AFT CARGO FLOOR STRUCTURE WEB CUT OUT HAS CORROSION UNDER NUT PLATES AT STA 1153 TO 1175, LBL 10 TO RBL 10.BLEND AND REMOVED CORROSION FROM STIFFENERS WITHIN LIMITS, FABRICATED STRAP, ALODINE PRIME AND TOP COAT AND INSTALLED AFT CARGO FLOOR STRUCTURE WEB CUT OUT @ STA 1153-1175 LBL 10-10R (LP 0965339)