What was found
ON WALK AROUND FOUND AFT LT FUSELAGE ABOUT 2 FT DOWN FROM AFT OF LT ENG PYLON A 2 IN SKIN CRACK. REMOVED EXISTING REPAIR. CUT OUT DAMAGED AREAS PER RI 575794-14 08-MAR-2019 2000E. PERFORMED HFEC OF CUTOUTS AND BHEC INSPECTION OF EXISTING FASTENER HOLES PER RI 575794-14 08-MAR-2019 2000E STEPS 4 AND 6. NO CRACKS INDICATED. FABRICATED AND INSTALLED DOUBLER AND FILLERS PER RI 575794-14 08-MAR-2019 2000E STEPS 7 THRU 15. (LP5516023)