What was found
THE EMERGENCY LIGHTS AT ROWS 15-19 ARE INOPERATIVE. MAINTENANCE INSTALLED A SERVICEABLE EMERGENCY LIGHT BATTERY POWER SUPPLY AND BATTERY PER AMM 33-51-03. (LP #5291341)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
THE EMERGENCY LIGHTS AT ROWS 15-19 ARE INOPERATIVE. MAINTENANCE INSTALLED A SERVICEABLE EMERGENCY LIGHT BATTERY POWER SUPPLY AND BATTERY PER AMM 33-51-03. (LP #5291341)