What was found
INITIAL INSPECTION: CRACK ON UPPER/FWD RING PAN STA 636 LT SIDE AT PAX CABIN. UPPER/FWD RING PAN STA 636 LT SIDE AT PAX CABIN WERE REPAIRED PER SRM 56-20-02-2R PROCEDURE 1, REPAIR 1, TYPE B. (ET) (HFEC) INSPECTION WAS ACCOMPLISHED ON UPPER/FWD RING PAN STA 636 LT SIDE AT PAX CABIN, NO CRACKS WERE FOUND AFTER TRIM OUT PER NDTSPM PART 6, 06-10-01.001. (LP1000455)