What was found
INITIAL INSPECTION: CRACK ON UPPER/AFT RING PAN STA Y=832 RT SIDE AT PAX CABIN. UPPER/AFT RING PAN STA Y=832 RT SIDE AT PAX CABIN WERE REPAIRED PER SRM 56-20-02-2R PROCEDURE 1, REPAIR 1, TYPE B. (ET) (HFEC) INSPECTION WAS ACCOMPLISHED ON UPPER/AFT RING PAN STA Y=832 RT SIDE AT PAX CABIN, NO CRACKS WERE FOUND AFTER TRIM OUT PER NDTSPM PART 6, 06-10- 01.001. (LP1000585)