What was found
SHIP 5654 INITIAL INSPECTION: CRACKED STRAP BELOW FLOOR BEAM AT STA 377 AND LBL=25 AT PAX CABIN FLOOR STRUCTURE. CORRECTIVE ACTION: SUMMARY OF NRC S/N 00219: STRAP WAS REPLACED PER ER/A: 384483-14MA REV. D. (1009349)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SHIP 5654 INITIAL INSPECTION: CRACKED STRAP BELOW FLOOR BEAM AT STA 377 AND LBL=25 AT PAX CABIN FLOOR STRUCTURE. CORRECTIVE ACTION: SUMMARY OF NRC S/N 00219: STRAP WAS REPLACED PER ER/A: 384483-14MA REV. D. (1009349)