Service difficulty report · Bolt · Boeing 717200

Difficulty date
April 5, 2019
Submitted
April 6, 2019
Operation
Air carrier
Aircraft
N964AT
Make and model
Boeing 717200
Aircraft serial
55025
Aircraft time
49,830 hours, 33,711 cycles
Part
Bolt
Condition
Frozen
Location
Rt Wing Te Flap
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RT WING, OUTBD FLAP HINGE PIVOT BOLT FROZEN, SEALER BROKEN INDICATING FROZEN RUSTED BOLT. REMOVED MIDDLE AND OUTBOARD HINGE BOLTS REF B717 AMM 27-50-01. REMOVED SEALER AND FOUND I/B FITTING LEG BOLT HOLE ELONGATED REF B717 AMM 27-50-01. MACHINED O/B LUG OUTER FACE AND I/B LUG BORE AND INNER FACE BEYOND REPAIR LIMITS PER OHM 27-50-5. COMPLIED WITH PRI 576897-14 REV. O & 1, FINAL ER/A 576897-14 REV. O MATCHES PRI 576897-14 REV. O & REV. 1. REF NRC 140 C-CK. REPLACED BUSHING IAW PRI 576897-14 #2. INSTALLED O/B WING FLAP HINGE BOLT, CENTER WING FLAP HINGE BOLT, AND O/B ACTUATOR CYLINDER BOLT IAW B717 AMM 27-50-01. RESEALED BOTH SIDE OF BOLT REF B717 AMM 27-50 01. (LP #1017937)

More about the Boeing 717-200