What was found
CORROSION ON FLOOR BEAM +Y1292 LOC. FR12 TO FR24 FWD GALLEY AREA ( 1 EA). EVALUATED FLOOR BEAM +Y1292 LOC FR 12 TO FR 24 FWD GALLEY AREA AND FOUND WITHIN LIMITS AS PER A319 SRM 53-00-15-101 STEP 2, F1601 SHEET 1 MEASUREMENT OF REWORKED AREA P1:L=2.237" W=0.368" D=0.020" P2:L= 1.411" W=0.346" D=0.016".