What was found
(LOG 1065704) DURING INSPECTION FOUND CORROSION FLOOR STRUCTURE BEAM LOC.BS986.5 AND LBL 43 AT AFT GALLEY AREA. PERFORMED PERMANENT REPAIR ON FLOOR STRUCTURE BEAM LOC. BS 986.5 AND LBL 43 AT FWD GALLEY AREA ASPER ER/A 464736-14MA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(LOG 1065704) DURING INSPECTION FOUND CORROSION FLOOR STRUCTURE BEAM LOC.BS986.5 AND LBL 43 AT AFT GALLEY AREA. PERFORMED PERMANENT REPAIR ON FLOOR STRUCTURE BEAM LOC. BS 986.5 AND LBL 43 AT FWD GALLEY AREA ASPER ER/A 464736-14MA.