Service difficulty report · Floor Support · Boeing 717200

Difficulty date
May 10, 2019
Submitted
May 13, 2019
Operation
Air carrier
Aircraft
N608AT
Make and model
Boeing 717200
Aircraft serial
55081
Aircraft time
38,415 hours, 33,049 cycles
Part
Floor Support
Condition
Corroded
Location
Fuselage
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CORROSION ON FLOOR SUPPORTS X7/X-7 BETWEEN STA 200/149 (CPAX). NRC 00430: CORROSION LEVEL 2, FLOOR SUPPORTS X7/X-7 BETWEEN STA 200/149 WERE REPLACED PER SRM 51-41-01-OG. ORIGINAL THICKNESS IS 0.125" AND REMAINING THICKNESS IS 0.080". THEREFORE ITS OUT OF LIMITS PER SRM 53-00-00-1A FIG. 103. (LP #1068829)