As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON FLOOR SUPPORT AT STA 148 FROM X=-31/-44 (CPIL). NRC 00560: LEVEL CORROSION 2, FLOOR SUPPORT AT STA 148 FROM X=-31/-44 WAS REPLACED PER B717-200 SRM 51-41-02-0G. ORIGINAL THICKNESS WAS 0.040" REMAINING THICKNESS IS 0.019", THEREFORE IT IS OUT OF LIMITS PER B717-200 SRM 51-10-02 PAR. 8(F) AND DWG #9936533-35. (LP #1116739)