What was found
CORROSION ON FLOOR SUPPORT FROM STA Y=1022 TO Y=1076 X=-20 AT CABIN PAX. CORROSION LEVEL 2, CORROSION WAS REMOVED PER B717-200 SRM 51-10-04-0G PAR 26. REMAINING THICKNESS IS ONLY 0.025 AND THEREFORE IS OUT OF LIMITS PER B717-200 SRM 53-00-00-1A ALLOWABLE DAMAGE PAR. 4 FIG. 103. FLOOR SUPPORT WAS REPLACED PER B717-200 DWG #9936656 REV: AM, SRM 51-40-08-0G, AND 51-20-09-0G.