What was found
INITIAL INSPECTION: CORROSION ON FUSELAGE SKIN BTW STA Y= 1022 - 1035 AND LONG 23L - 26L. CORROSION LEVEL 2 IN REF OF NRC 00063 AREA WAS REPAIRED PER ER/A 578990-14 REV ORIGINAL AND ETI-17-19-085 REV 3. TIME CONTROLLED ITEMS: ACCOMPLISH SECTION II: REPETITIVE INSPECTIONS EVERY 8,000 FLIGHT CYCLES AFTER ACCOMPLISHMENT OF SECTION I: PERMANENT REPAIR, AND FOLLOWED UNDER LOG PAGE 1150080. ASSOCIATED ER/A 14-578990 ADDED FOR AC 9503. (LP1153204)