What was found
INITIAL INSPECTION: CRACK ON FUSELAGE SKIN AT STA Y=1087 BTW LONG 13L TO 14L. PERMANENT REPAIR WAS PERFORMED ON FUSELAGE SKIN AT STA Y=1087 BTW LONG 13L TO 14L PER ERA 579428-14 REV. ORG. SECTION I AND ETI 17-19-081 REV. 5. REPETITIVE INSPECTION WITHIN EVERY CCK(NOT TO EXCEED 24 MONTHS) INTERVAL AFTER ACCOMPLISHMENT OF SECTION I. PER ER/A 579428-14 REV. ORIGINAL SEC. II. WILL BE PERFORMED UNDER LOG PAGE 1153262. (LP1155385)