What was found
INITIAL INSPECTION: TOOL MARKS AND WEAR ON FRAME AND PREVIOUS REPAIR STA Y=1520 (BTW STRINGER 24RH-26RH) AT AFT CARGO COMPARTMENT (C2). PREVIOUS REPAIR WAS REPLACED PER ER/A 088365-14 REV. ORIG AND ALSO WAS REWORKED PER B757-200 SRM 51-10-02 PAR. 6. (UT) WAS ACCOMPLISHED ORIGINAL THICKNESS IN FRAME IS .063" AND MINIMMUM REMAINING THICKNESS IS .058" THEREFORE ITS WITHIN LIMITS PER B757-200 SRM 53-00-07 AD 1.