What was found
TAXING INTO RAMP, BIG SPARK OUT OF CAPT WINDSHIELD ANTI-ICE CONNECTOR. FOUND WIRE TERMINAL IN CONTACT WITH SPRING ON WINDOW TEMP SENSOR. ADJUSTED WIRE TERMINAL FOR CLEARANCE. CKS OK. (LP5490390)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TAXING INTO RAMP, BIG SPARK OUT OF CAPT WINDSHIELD ANTI-ICE CONNECTOR. FOUND WIRE TERMINAL IN CONTACT WITH SPRING ON WINDOW TEMP SENSOR. ADJUSTED WIRE TERMINAL FOR CLEARANCE. CKS OK. (LP5490390)