As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CRACK INDICATION ON FRAME 16 UPPER INBD FASTENER HOLE AT DOOR STOP 7 L H SIDE, CRACK DIRECTION IS 5 OCLOCK AND DEPTH IS 0.150 INCH. WORK CARD 5311-2031, SSI 531103 AT FWD GALLEY AREA (1 EA). REPLACED INTERCOSTAL FITTING AND FASTENERS LOCATED ON FRAME 16 AT DOOR STOP 7LH SIDE AT FWD GALLEY AREA AS PER SRM A320 51-72-11 AND DRAWING D53114223.