What was found
CRACK INDICATION ON FRAME 16 LOWER INBD FASTENER HOLE AT DOOR STOP 1 RH SIDE, CRACK DIRECTION 6 AND 9 OCLOCK AND DEPTHS ARE 0.080 INCH AND 0.020 INCH WORK CARD 5311-2031, SSI 531103. AT FWD GALLEY AREA (2 EA). PERFORMED PERMANENT REPAIR ON HOLE #3 AT DOOR STOP #1 ON FR 16 R/H ASPER PRI 580094-14 REV 0 AND REV 1 AND ER/A #580094-14AD REV ORIGINAL.