As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CRACK INDICATION ON FRAME 20 (RH) FROM THE UPPER I/B HOLE COMMON TO DO OR STOP FITTING 7 AT FWD GALLEY AREA (1 EA) (CRACK DIRECTION IS 7 O'C LOCK LOOKING AFT) (THE CRACK LENGTH IS 0.058 INCHES). PERFORMED PERMANENT REPAIR LOC ON FRAME 20 RH COMMON TO DOOR STOP FITTING 7 AT FWD GALLEY AREA ASPER PRI REV 0-1 AND ERA 579968-14AD REV ORIGINAL.