What was found
DURING INSPECTION FOUND CORROSION ON FLOOR BEAM STA 986 BTW LBL 46 AND RBL 46 AT AFT WET AREA. FLOOR BEAM STA 986 BTW LBL 46 AND RBL 46 AT AFT WET AREA WAS REPAIRED PER B737-800 SRM 53-70-51 REPAIR 4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION FOUND CORROSION ON FLOOR BEAM STA 986 BTW LBL 46 AND RBL 46 AT AFT WET AREA. FLOOR BEAM STA 986 BTW LBL 46 AND RBL 46 AT AFT WET AREA WAS REPAIRED PER B737-800 SRM 53-70-51 REPAIR 4.