What was found
CRACK FLOOR STRUCTURE WEB BTW FR 68 TO FR 69 AT LEVEL STR-23L SIDE AT AFT GALLEY AREA, REPLACED FLOOR STRUCTURE WEB BTW FR 68 TO FR 69 AT LEVEL STR 25L SIDE AT AFT GALLEY AREA (1EA) ASPER SRM 51-72-11 AND DWG # D53480020.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK FLOOR STRUCTURE WEB BTW FR 68 TO FR 69 AT LEVEL STR-23L SIDE AT AFT GALLEY AREA, REPLACED FLOOR STRUCTURE WEB BTW FR 68 TO FR 69 AT LEVEL STR 25L SIDE AT AFT GALLEY AREA (1EA) ASPER SRM 51-72-11 AND DWG # D53480020.